edra6,Air Velocity Meter,Volume Flow Meter,dz¼Ó°è,dz·®°è,ÈÞ´ë¿ë dz¼Ó°è,ÈÞ´ë¿ë dz·®°è,Air Flow,dz¼Ó ÃøÁ¤,dz·® ÃøÁ¤">

 ÀÀ¿ë ±â°èº°(¹°)

 ÀÀ¿ë ±â°èº°(°ø±â)

 ±â»ó °üÃøÀåÄ¡

 ±âŸ °üÃøÀåÄ¡

 Á¦ÀÛ ½ÇÇèÀåÄ¡

 

 

 

  ÇöÀçÀ§Ä¡ : HOME > Á¦Ç°Á¤º¸ > ÀÀ¿ë ±â°èº° > dz¼Ó/dz·® ÃøÁ¤ ÀåÄ¡ > EDRA6

 

          EDRA6 (Electronic Direct Reading Anemometer)

 

  Reads in m/sec and ft/min

  Choice of 100mm or 35mm dia. Rotating vane head

  Three velocity ranges in one meter

  Output facility for data logging

  Fast response with superb accuracy

  Telescopic probe with articulating head

  Battery or mains operated

  3 scales for enhanced resolution

 

 

 

 

 

 

 

 

  ACCURACY AND PRECISION - EVERY TIME

 

  The EDRA 6 is an electronic anemometer providing virtually instantaneous readings of air

     velocity in m/sec and ft/min on a large, clear analogue meter. The display has three user

     selectable measurement ranges, colour coded for ease of reading, to ensure excellent

     resolution particularly in critical low velocity situations.

 

  Using the instrument is simplicity itself. whether using battery or mains power via the battery

    eliminator (optional).

 

  Using the industry standard 100 mm (4") rotating vane supplied or a 35 mm (1.4") rotating

    vane sensor (optional extra), a variety of applications can be measured quickly and

    accurately. The outstanding versatility of EDRA 6 is further enhanced using the telescopic

    extension handle which provdes rigid support of the vane sensor up to 1.1m in length.

    Incorporating a lockable "all angle" swivelling tip, alignment of the sensor in the airstream is

    possible even where access is limited. The instrument is also equipped with an analogue

    output on each velocity range so that measured values may be downloaded to a compatible

    printer or data logger such as the AirflowTM AM2.

 

  Contained in a durable moulded plastic enclosure, EDRA 6 is supplied complete with a

    protective carrying vase, designed to withstand the rigours of on-site use, with ample

    storage space for accessories and documentation.

 

  An extremely helpful option is the AIRCONE kit. An inexpensive kit containing a circular and

    rectangular moulded hood for air balancing which simply clips onto the vane probe to

    provide direct air volume flow readings from grilles, linears and diffusers.

 

  Calibrated to an Internationally recognised standard the EDRA 6 is supplied with a FREE

    TRACEABLE CERTIFICATE OF CALIBRATION and a reply card is also included for purchasers

     to register with our FREE annual calibration reminder service.

 

  All AirflowTM instruments, including the EDRA 6, are designed to help meet the stringent

    requirements of the Control Of Substances Hazardous to Health (COSHH) and Building

    Regulations in the UK.

 

  For our UK customers the reminder card service ensures valid certification for COSHH,

    ISO9001 and Quality Assurance requirements.

 

 

 

 

 

 EDRA6

Parameter Metric Mode Imperial Mode
Velocity range 5 - 25 m/sec
1 - 5 m/sec
0.25 - 1 m/sec
1000 - 5000 ft/min
190 - 1000 ft/min
50 - 190 ft/min
Accuracy at 20¡ÆC and 1013 mbar
(68¡ÆF and 30 in Hg)
100mm diameter sensor
(main head)
Calibrated to better than ¡¾1% of reading and:
5 - 25 m/sec, ¡¾0.05 m/sec
0.25 - 5 m/sec, ¡¾0.02 m/sec
1000 - 5000 ft/min, ¡¾10 ft/min
50-1000 ft/min, ¡¾4 ft/min
35mm diameter sensor
(optional extra)
1 - 20 m/sec, ¡¾2% of reading
and ¡¾0.05 m/sec
0.4-1 m/sec, ¡¾5% of reading
and ¡¾0.02 m/sec
190 - 4000 ft/min, ¡¾2% of reading
and ¡¾10 ft/min
80 - 190 ft/min, ¡¾5% of reading
and ¡¾4 ft/min
Operating Environment Barometric pressure: 500 mbar to 2 bar
Temperature: -10¡ÆC to 60¡ÆC
Barometic pressure: 15 in Hg to 60 in Hg
Temperature: 14¡ÆF to 140¡ÆF
Operating Environment
Head only
Short periods to -30¡ÆC Short periods to -22¡ÆF
Power Supply 4 type 1.5 volt cell, IEC R20 or equivalent (standard, alkaline or rechargable)
Battery Life Approximately 800 hours using standard batteries
Analogue Output 0 - 1mA on each range (max. load 2k ohms)
Overall Dimensions 255mm ¡¿ 240mm ¡¿ 118mm 10 in ¡¿ 9.4 in ¡¿ 4.6 in
Weight (less batteries) 1.6kg 3.5 lbs
Standard kit EDRA6 Meter
100mm (4 in) diameter vane sensor
Telescopic extension and handle
Plug for output socket
Padded carry case
Adjustable neck strap
Calibration certificate to BMT standards
Operating guide
Optional accessories 35mm (1.4 in) diameter vane sensor
Battery eliminator for mains operation
Vane sensor extension cables (max. 100m)
Aircone kit for air balancing
Optional instrumentation AM2 Data Logger
OC20 output converter providing 4 - 20mA, 0 - 20mA or 0 - 1v from analogue output

 

 